Special Features:
Superior impulse performance up to 200000 cycles. Thicker cover for high abrasion resistance. Cover designed to dissipate static electricity and to prevent fire hazards inside mines.
 

PIX - MINING PRO (Standards: BCS 174. EXCEEDS ISO 6805 TYPE 2)

Product
Code
Dash DN
Hose ID
(inch)
 
Hose ID
(mm)
Braid OD
(mm)
Hose OD
(mm)
Maximum Working
Pressure
Minimum Burst
Pressure
Minimum Bend
Radius
Weight
Meter
Kgs/mtr
MPa bar psi MPa bar psi mm
MO206 -4 6 1/4 6.4 12.7 16.7 45.0 450 6525 180.0 1800 26100 100 0.430
MO210 -6 10 3/8 9.5 16.9 21.3 38.0 380 5510 152.0 1520 22040 130 0.670
MO212 -8 12 1/2 12.7 21.0 26.3 36.2 362 5249 144.8 1448 20996 150 0.865
MO219 -12 19 3/4 19.0 28.3 33.6 27.6 276 4002 110.4 1104 16008 230 1.295
MO225 -16 25 1 25.4 35.5 40.2 21.5 215 3118 86.0 860 12470 300 1.650
MO231 -20 31 1-1/4 31.8 41.5 47.2 17.2 172 2494 68.8 688 9976 380 2.095
MO238 -24 38 1-1/2 38.1 48.0 53.8 14.6 146 2117 58.4 584 8468 450 2.385
MO251 -32 51 2 50.8 60.7 66.2 11.2 112 1624 44.8 448 6496 600 3.020

Application:
Underground mining requiring very stringent safety standards like Long-wall mining and roof support system. Hydraulic circuits in fire hazardous environments.

Working temperature: - 40°C to + 100°C (Continuous).
Intermittent temperature: - 40°C to + 120°C (10% of total working hours)
Special MSHA approved flame resistant outer cover can be provided on request
Note: 1MPa = 10 bar = 145 psi

<<BACK<<
 